Dairy Division TR4C-1M |
|
|
|
||
|
Company profile
Divisions
|
|
Temperature recorder
|
|
The
TR 4C-1M is the first system combining the record and the temperature
certification of a frozen product transportation as well as the respect of
the cold chain. The 2 copies of the report (one for the customer and one
for the carrier) give the average temperature hour per hour and all the
possible alarms from the departure up to the arrival. The
TR4C-1M recorder has been designed to solve the transport certification,
it complies with the DMN 493 norm of 9/25/95 and also the HACCP regulation
concerning the respect of the cold chain of a fresh or frozen product
transportation. This is also the best way to guarantee the transportation and to avoid any litigation between a customer and a supplier of a perishable product.
Characteristics The
TR4C-1M includes the following components : ·
the
recorder , including a 4 digits LED display, in which temperature of the
probes and time are shown successively. ·
a
printer. ·
an
Alarm signal (LED + Sound). ·
a
keyboard to set the alarm level and all the user definable parameters. The
central unit collects all the data coming from the 4 temperature probes,
allowing , using an extra connector, to control eventually the safety
fridge generator on the truck. The temperature probes with active sensors are delivered with variable length from 1 to 15 m.
Specifications ·
Easy
to use, user definable parameters (date, time, alarm min & max level
(0.5°C resolution), measurement frequency (1 to 20 min), travel starting
point….), all data are downloadable to a PC via RS232 Port. ·
Reports
: average temperature hour per hour from the beginning of the travel, min
& max temperature hour per hour from the beginning of the travel, all
the measured temperature during the travel, full Travel report (date &
time of departure, average temperature hour per hour, ·
The
TR4C-1M record all eventual anomalies (Power supply, Probe… ), and the
date . ·
Power
Supply : 12 to 30 V cc ; 500mW with
recorder and display off, 10 W with printer and display on. ·
Memory
capacity : 8000 measurements. · Measurement frequency : User definable : 1,2,3,4,5,6,10,15,20 min. ·
Temperature
Range : -55° C / + 125°C.
|
||